Shrnutí obsahu

Strany 1 - Reference Manual

www.datalogic.comDS1500Reference Manual

Strany 2

GENERAL VIEW DS1500 2 1 3 4 56 7 9 1011 8 Figure A 1 2 3 4 8765Mounting Holes Good Read LED External Trigger/Ready LED Tx Data/Active LED Las

Strany 3 - CONTENTS

GUIDE TO INSTALLATION The following can be used as a checklist to verify all of the steps necessary for complete installation of the DS1500 scanner

Strany 5 - REFERENCES

INTRODUCTION 1 1 INTRODUCTION 1.1 PRODUCT DESCRIPTION The new DS1500 industrial laser scanner is the combination of extremely compact dimension and

Strany 6 - SAFETY REGULATIONS

DS1500 1 1.2 APPLICATIONS DS1500 target applications are primarily OEM integration in application characterized by space constraints, demanding readi

Strany 7 - POWER SUPPLY

INTRODUCTION 1 1.4 INDICATORS The five LEDs indicate the following: LED Standard Mode Test Mode Restore Double RS232 POWER ON (green) (Figure A,

Strany 8 - WEEE COMPLIANCE

DS1500 1 1.5 TEST KEY FUNCTIONING DS1500 provides an external key, which can be used for the following: - Restoring dual RS232 interface at power

Strany 9

INTRODUCTION 1 1.5.2 Activating Test Operating Mode To launch the Test Mode by the external key, proceed as follows: 1. From any operating mode, pr

Strany 10 - GENERAL VIEW

DS1500 1 NOTE The Test Mode is not permanently saved. NOTE You must not be in Test Mode activated by Test Key when configuring DS1500 parameters.

Strany 11 - GUIDE TO INSTALLATION

INSTALLATION 2 2 INSTALLATION 2.1 PACKAGE CONTENTS Verify that the DS1500 reader and all the parts supplied with the equipment are present and inta

Strany 12

DATALOGIC S.p.A. Via Candini 2 40012 - Lippo di Calderara di Reno Bologna - Italy DS1500 Reference Manual Ed.: 11/2007 AL

Strany 13 - 1 INTRODUCTION

DS1500 2 2.2 MECHANICAL INSTALLATION DS1500 can be installed to operate in different positions. The two screw holes (M2 x 4) on the body of the reade

Strany 14 - DS1500 - X X 0 0

INSTALLATION 2 3.2 [0.13]3.2 [0.13]=11 [0.43]6 [0.24]=62 [2.44]20 [0.79]25 [0.98]1.5 [0.06]inchmm7.1 [0.28]31.8 [1.25]31.8 [1.25]25.1 [0.99]12 [0.47]

Strany 15 - 1.4 INDICATORS

DS1500 2 2.2.1 Mounting DS1500 Using the DS1500 mounting bracket you can obtain the most suitable position for the reader as shown in the figure belo

Strany 16 - 1.5 TEST KEY FUNCTIONING

INSTALLATION 2 2.3 ELECTRICAL CONNECTIONS All DS1500 models are equipped with a cable terminated by a 15-pin male D-sub high-density connector for co

Strany 17 - INTRODUCTION

DS1500 2 2.3.1 Power Supply Power can be supplied to the scanner through the pins provided on the 15-pin connector used for communication with the ho

Strany 18 - 1.6 ACCESSORIES

INSTALLATION 2 RS232 Interface The serial interface is used in this case for point-to-point connections; it handles communication with the host compu

Strany 19 - 2 INSTALLATION

DS1500 2 RS485 Full-Duplex Interface The RS485 full-duplex (5 wires + shield) interface is used for non-polled communication protocols in point-to-po

Strany 20 - 2.2 MECHANICAL INSTALLATION

INSTALLATION 2 RS485 Half-Duplex Interface The RS485 half-duplex (3 wires + shield) interface is used for polled communication protocols. It can be

Strany 21 - INSTALLATION

DS1500 2 Figure 10 shows a multidrop configuration with DS1500 scanners connected to a Multiplexer. CAUTION To avoid any possible Ground loop, keep

Strany 22 - 2.2.1 Mounting DS1500

INSTALLATION 2 2.3.3 Auxiliary RS232 Interface The auxiliary serial interface is used exclusively for RS232 point-to-point connections. The paramet

Strany 23 - 2.3 ELECTRICAL CONNECTIONS

CONTENTS REFERENCES ... v Conventions ...

Strany 24 - 2.3.2 Main Serial Interface

DS1500 2 Code Verifier If the DS1500 is used as a Code Verifier, it is possible to indicate to the scanner what code to store as the verifier code th

Strany 25 - RS232 Interface

INSTALLATION 2 An anti-disturbance hardware filter is implemented on the External Trigger input (< 5 milliseconds delay). An additional 15 ms (ty

Strany 26 - RS485 Full-Duplex Interface

DS1500 2 2.4 USER INTERFACE The following table contains the pinout for standard RS232 PC Host interface. For other user interface types please refer

Strany 27 - RS485 Half-Duplex Interface

INSTALLATION 2 2.5 POSITIONING The DS1500 scanner is able to decode moving barcode labels at a variety of angles, however significant angular distort

Strany 28 - CAUTION

DS1500 2 The Tilt angle is represented by the value T in Figure 17. Position the reader in order to minimize the Tilt angle. TFigure 17 - Tilt Angl

Strany 29

INSTALLATION 2 2.6 TYPICAL LAYOUTS The following typical layouts refer to system hardware configurations. Dotted lines in the figures refer to option

Strany 30 - 2.3.4 Inputs

DS1500 2 In this layout the data is transmitted to the Host on the main serial interface. Host Mode programming can be accomplished through the main i

Strany 31 - 2.3.5 Outputs

INSTALLATION 2 2.6.2 Pass-Through Pass-through mode allows two or more devices to be connected to a single external serial interface. Each DS1500 tr

Strany 32 - 2.4 USER INTERFACE

DS1500 2 2.6.3 RS232 Master/Slave The RS232 master/slave connection is used to collect data from several scanners to build either a multi-point or a

Strany 33 - 2.5 POSITIONING

INSTALLATION 2 2.6.4 Multiplexer Layout Each scanner is connected to a Multiplexer (for example MX4000) with the RS485 half-duplex main interface.

Strany 34 - Figure 17 - Tilt Angle

3 READING FEATURES... 28 3.1 Advanced Code Builder (ACB)...

Strany 35 - 2.6.1 Point-to-Point

DS1500 3 3 READING FEATURES 3.1 ADVANCED CODE BUILDER (ACB) In addition to linear reading, the Advanced Code Builder (ACB) allows code reading by

Strany 36

READING FEATURES 3 ACB Readable ACB is disabled by default but can be enabled for the following code types: • Code 25 Interle

Strany 37 - 2.6.2 Pass-Through

DS1500 3 3.1.2 Tilt Angle Improvement with ACB ACB allows barcode reading with an increased tilt angle. The tilt angle depends upon the code aspect

Strany 38 - 2.6.3 RS232 Master/Slave

READING FEATURES 3 3.2.1 Step-Ladder Mode If scanning is perpendicular to the code motion direction (Figure 23), the number of effective scans perfor

Strany 39 - 2.6.4 Multiplexer Layout

DS1500 3 3.2.2 Picket-Fence Mode If scanning is parallel to the code motion, the number of effective scans is given by the following formula: SN = [

Strany 40 - 3 READING FEATURES

READING FEATURES 3 3.3 PERFORMANCE The DS1500 scanner has the following performances: Version Max Code Resolution Speed mm (mils) scans/s 1100

Strany 41 - Valid for ACB

DS1500 3 3.4 READING DIAGRAMS DS1500-1100 2 1 0 1 5 4 3 2 3 4 5 (in) 0 1 32 106(in) 45 7 890 20 40 60 80 100 120140160180200220240260(mm) 12010080

Strany 42 - 3.2 LINEAR CODE READING

READING FEATURES 35 3 DS1500-2100 1 0.5 0 0.5 2.5 2 1.5 1 1.5 2 2.5 (in) 01 53(in) 240 10 20 30 40 50 60708090100110120130(mm) 60 50 40 3020100102

Strany 43 - 3.2.1 Step-Ladder Mode

DS1500 4 4 MAINTENANCE 4.1 CLEANING Clean the laser beam output window periodically for continued correct operation of the reader. Dust, dirt, etc

Strany 44 - 3.2.2 Picket-Fence Mode

TROUBLESHOOTING 5 5 TROUBLESHOOTING 5.1 GENERAL GUIDELINES When wiring the device, pay careful attention to the pin number of the signals. If you

Strany 45 - 3.3 PERFORMANCE

REFERENCES CONVENTIONS This manual uses the following conventions: “User” or “Operator” refers to anyone using a DS1500. “Device” refers to the DS

Strany 46 - DS1500-1100

DS1500 5 TROUBLESHOOTING GUIDE Problem Suggestions Power On: the “Power On” LED is not lit Is power connected? If using a power adapter (like PG 220

Strany 47 - DS1500-2100

TROUBLESHOOTING 5 TROUBLESHOOTING GUIDE Problem Suggestions Reading: Not possible to read the target barcode (always returns No Read) Check synchron

Strany 48 - 4 MAINTENANCE

DS1500 6 6 TECHNICAL FEATURES ELECTRICAL FEATURES Input Power Supply voltage 5 Vdc ± 5% Power consumption max. 2 W Serial Interfaces Main RS23

Strany 49 - 5 TROUBLESHOOTING

TECHNICAL FEATURES 6 SOFTWARE FEATURES READABLE CODE SYMBOLOGIES * EAN/UPC * Code 93 EAN/UPC (including Add-on 2 and Add-on 5) * Code 128 * 2/5

Strany 50

DS1500 A A DEFAULT CONFIGURATION The following table shows the default values of the Standard Application Program configuration Parameters. Paramet

Strany 51 - TROUBLESHOOTING

DEFAULT CONFIGURATION A Parameter Default SettingAdvanced Code Options Linear Reading Options Required Quiet Zone Both ACB Parameters Max Scan Gap

Strany 52 - 6 TECHNICAL FEATURES

DS1500 A Parameter Default SettingAuxiliary Interface Parameters Communication Mode Local Echo Baud Rate 9600 Parity None Data Bits 8 Stop Bits 1

Strany 53 - (Note 3)

DEFAULT CONFIGURATION A Parameter Default SettingData Format (continued) Data Packet Separator 2 <LF> Terminator 1 <CR> Terminator 2

Strany 54 - A DEFAULT CONFIGURATION

DS1500 A Parameter Default SettingReading Parameters Beam Shutter Triggered Overflow Automatic Overflow Ratio 7 Motor Control Speed_4 Serial Motor

Strany 55 - DEFAULT CONFIGURATION

GLOSSARY ACB (Advanced Code Builder) Advanced Code Builder (ACB) allows code reading by “stitching” together two partial reads of it. ACB is effect

Strany 56

SAFETY REGULATIONS LASER SAFETY The following information is provided to comply with the rules imposed by international authorities and refers to

Strany 57

meaningful data and provides the interface to other devices. The decoder is normally integrated into the scanner. EAN European Article Number System

Strany 58

Pitch Rotation of a code pattern about the X-axis. The normal distance between center line or adjacent characters. See pars. 2.2.1 and 2.5. Position

Strany 59 - GLOSSARY

Step-Ladder orientation When the barcode’s bars are positioned horizontally on the product, causing them to appear as a ladder. The ends of all bars

Strany 60

INDEX A Accessories; 6 Advanced Code Builder; 28 Applications; 2 C Cleaning; 35 E Electrical Connections; 11 Auxiliary RS232 Interface; 17 Inputs;

Strany 61

DECLARATION OF CONFORMITY 07 Datalogic Automation S.r.l., Via S. Vitalino 13 40012 - Lippo di Calderara Bologna - Italy dichiara che declares that

Strany 62

www.datalogic.comDS1500Reference Manual

Strany 63

Warning labels indicating exposure to laser light and the device classification are applied onto the body of the scanner (Figure A, 6). Warning and

Strany 64

CE COMPLIANCE Warning: This is a Class A product. In a domestic environment this product may cause radio interference in which case the user may be